HK 100LA4 B35 2-4 IE3

E-Motor 230/400V 2,2kW 1455U B3/B5 IE3
P 50 Hz
2.2 kW
n 50 Hz
1,465 r/min
P 60 Hz
2.55 kW
Download PDF
Registreer u nu om onze online shop op te kunnen roepen.

Register now and access our complete product range and many exclusive services.

Product details for

HK 100LA4 B35 2-4 IE3

P 50 Hz
2.2 kW
n 50 Hz
1,465 r/min
P 60 Hz
2.55 kW
n 60 Hz
1,765 r/min
LF 50 Hz
0.83
Factor IA / IN
7
η (IE3) %
87
A
160 mm
B
373 mm
C
280 mm
H
100 mm
I 50 Hz
7.65 A
Ø D shaft
28 mm
Ø E
180 mm
Ø F
250 mm
All characteristics

Characteristics

Schutzart
  • IP 55 
Umgebungstemperatur
  • -20 °C bis +40 °C 
Werkstoff
  • Gehäuse: Aluminium 
Ausführung
  • Bauform B3 / B5 
  • Füße demontierbar 
Zolltarifnummer
  • 85015220 
All characteristics

Productbeschrijving

Notes
Caution! Measurement »B« can depending on design slightly vary in length.
Description
Self-cooling squirrel-cage energy-saving motors.
High efficiency IE3 - IEC60034-30:2009.
Rated voltage 230/400 V 50 Hz, 460 V 60 Hz.
4-pin.
Voltage tolerance ±5 %.

Product variants

5 Results
Show dimensional drawing
Identifier
P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
P 50 Hz = nominal output at 400 V/50 Hz
η (IE3) = efficiency to IE3 in % (at full load)
Factor IA / IN = start-up current IA / Nominal current IN

Column selection

P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
LF 50 Hz
Factor IA / IN
η (IE3) %
A (mm)
B (mm)
C (mm)
H (mm)
I 50 Hz (A)
Ø D shaft (mm)
Ø E (mm)
Ø F (mm)
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
P 50 Hz = nominal output at 400 V/50 Hz
η (IE3) = efficiency to IE3 in % (at full load)